Appleton® EYS1

Appleton® UNILETS® EYS1 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 1/2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated

  • MPN: EYS1

  • IESPN: 198803

  • UPC: 781381704687

  • Min Order Qty: 1

  • Quantity Interval: 1

  • Sold as: EACH
    • Availability: loading

    • Branch Availability
Appleton® EYS1

These Appleton® sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another. They prevent pressure piling within the conduit system and contain any explosion that occurs. These models in the EYS series provide a close turning radius and can be used for sealing vertical conduit runs.

Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYS, 1/2 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Gray, Triple Coated, 3.28 in L x 1.25 in W

Type      Dust-Ignitionproof Explosionproof Raintight
Series      EYS
Size      1/2 in
Suitable For Use With      IMC/Threaded Rigid Metallic Conduit
Material      Grayloy-Iron
Color      Gray
Finish      Triple Coated
Dimensions      3.28 in L x 1.25 in W
  • Smooth, rounded integral bushing in each hub to protect conductor insulation
  • Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
  • Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
  • Large opening for damming and filling
  • Restrict any explosion to the sealed off enclosure
  • Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
  • Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
  • Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
  • Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
  • Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
  • Tapered FNPT connection
  • 25% fill vertical sealing fittings for close turning radius
  • Chromate/epoxy powder coated/zinc electroplated finish

    Availability By Branch

    Branch Name Available

    Write Review

    Atleast 50 Characters. You can Express Upto 1000 Characters

    An Email Id is required to process your orders. Please enter your email id and click update.