GE THPR3616BET1

GE HPC™ THPR3616BET1 Type THPR Bottom Feed Fusible High Pressure Contact Switch With Electric Trip, 120 to 240 VAC, 1600 A, 3 Poles

  • MPN: THPR3616BET1

  • IESPN: 60747

  • UPC: 783164161571

  • Min Order Qty: 1

  • Quantity Interval: 1

  • Sold as: EACH
    • Availability: loading

    • Branch Availability
GE THPR3616BET1

GE Type HPC™ switches are UL listed in accordance with standard 977, fused power circuit devices. The charge after close mechanism provides stored energy, quick-make/quick-break operation. Multiple spring loaded high pressure current carrying contact arms and an arcing contact arm provide excellent current carrying capability without sacrificing high interrupting fault performance. These switches are 100% rated and can interrupt, on a make and break basis, a minimum of 12 times their nameplate rating without fuse assistance at 600 VAC. Complete HPC™ switch and class L fuse coordination is therefore achieved for all levels of fault current up to 200000 rms A symmetrical at 600 VAC maximum. Type HPC™ switches used as service disconnects comply with the NEC Article 110.10 for adequate short circuit current and ground fault protection.

GE HPC™ High Pressure Contact Switch, Type THPR Bottom Feed Fusible, 120 to 240 VAC, 1600 A, 3 Phase, 50/60 Hz, 3 Poles, 200 kA Short Circuit, 30 in H x 25 in W x 8.66 in D

Type      Type THPR Bottom Feed Fusible
Voltage Rating      120 to 240 VAC
Amperage Rating      1600 A
Phase      3
Frequency Rating      50/60 Hz
Number of Poles      3
Short Circuit Current Rating      200 kA
Dimensions      30 in H x 25 in W x 8.66 in D
  • High durability safety of operation
  • High interrupting capability
  • High transient voltage withstand ability
  • Extended switch life
  • Positive ON-OFF indication
  • Easy operation, quick make
  • Emergency open, quick break
  • Fuse mounting bolts for ease of mounting fuses
  • Padlocking provisions standard
  • For use with ground Break™ components or for remote tripping
  • For resistance grounded systems or where zone selective interlocking is required, electric trip HPC™ switches with ground Break™ system components are recommended
  • 200 kA at 480 VAC short circuit rating
  • For use with TDF/TDR/TDM circuit breakers