GE THQL1115HID

GE Q-Line® THQL1115HID Type THQL Residential Circuit Breaker, 120/240 VAC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip

  • MPN: THQL1115HID

  • IESPN: 55543

  • UPC: 783164160055

  • Min Order Qty: 1

  • Quantity Interval: 1

  • Sold as: EACH
    • Availability: loading

    • Branch Availability
GE THQL1115HID

Q-Line circuit breakers are 1 in W per pole, compact, thermal magnetic devices designed for residential and commercial applications. The QB breakers are bolt-on versions of the Q-Line used for bolting to the bus connections of load centers and lighting panels. All Q-Line circuit breakers feature quick-make/quick-break mechanisms, common trip bars and easy to spot trip indication to ensure safety and reliability. Q-Line breakers are available in 1, 2 and 3-pole versions, can be ordered with auxiliary contact and shunt trip accessories and can be ordered for use in HID applications.

GE Q-Line® Residential Circuit Breaker, Type THQL, 120/240 VAC, 15 A, 50 to 60 Hz, 10 kA Interrupt, Q-Line Frame, Thermal Magnetic Trip, 1 Pole, 1 ph, Pivot Handle Actuator, Load Lug, 14 to 8 AWG, 12 to 8 AWG Wire, Plug-In Mount, 10 to 50 deg C, 1 in W x 2-3/8 in D x 3-9/32 in H, Plastic

Type      Type THQL
Voltage Rating      120/240 VAC
Amperage Rating      15 A
Frequency Rating      50 to 60 Hz
Interrupt Rating      10 kA
Frame      Q-Line
Trip Type      Thermal Magnetic
Number of Poles      1
Phase      1
Actuator Type      Pivot Handle
Connection Type      Load Lug
Wire Size      14 to 8 AWG, 12 to 8 AWG
Mounting Type      Plug-In
Temperature Rating      10 to 50 deg C
Dimensions      1 in W x 2-3/8 in D x 3-9/32 in H
Material      Plastic
  • Copper stabs, tin plated for corrosion resistance, make the connection reliable and permanent
  • Heat resistant thermoset cases and covers add stability and structural rigidity
  • Trips are easy to spot because handles trip to the center position
  • The dedicated calibration screw is cemented (not simply papered over) to prevent shifting, the result is stable calibration for optimum trip performance
  • HID breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HID lamps, are switched on and off
  • 14 to 8 AWG Cu, 12 to 8 AWG Al wire range
  • 10 kA at 120 VAC, 10 kA at 120/240 VAC interrupt rating

    Availability By Branch

    Branch Name Available

    Write Review

    Atleast 50 Characters. You can Express Upto 1000 Characters

    An Email Id is required to process your orders. Please enter your email id and click update.