EATON N48M28T75EE

EATON N48M28T75EE Type KT-13 Energy Efficient Non-Linear Ventilated Transformer, 480 Delta V Primary, 208Y/120 V Secondary, 75 kVA Power Rating, 60 Hz, 3 ph

  • MPN: N48M28T75EE

  • IESPN: 140432

  • UPC: 786680051425

  • Min Order Qty: 1

  • Quantity Interval: 1

  • Sold as: EACH
    • Availability: loading

    • Branch Availability
EATON N48M28T75EE

Eaton's K-Factor Transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformer’s winding insulation which prevents insulation breakdown and premature failure. The net result is longer transformer life.

EATON Transformer, Type KT-13 Energy Efficient Non-Linear Ventilated, 480 Delta V Primary, 208Y/120 V Secondary, 75 kVA Power, 60 Hz Frequency, 3 ph, 6 Taps, Lug Connection, 916A Frame Circuit, 220 deg C Insulation, NEMA 2 Enclosure, 150 deg C, Aluminum Winding, Steel Housing Material, 23.42 in L x 28.22 in W x 48.56 in H Dimensions

Type      Type KT-13 Energy Efficient Non-Linear Ventilated
Primary Voltage      480 Delta V
Secondary Voltage      208Y/120 V
Power Rating      75 kVA
Frequency Rating      60 Hz
Phase      3
Number of Taps      6
Connection Type      Lug
Circuit Type      916A Frame
Insulation      220 deg C
Enclosure Type      NEMA 2
Temperature Rating      150 deg C
Winding Material      Aluminum
Housing Material      Steel
Dimensions      23.42 in L x 28.22 in W x 48.56 in H
  • Includes transformers with DOE 2016 and NEMA TP-1 efficiency requirements and transformers with other efficiency requirements
  • Specially designed to withstand the harmful overheating effects caused by harmonics generated by nonlinear (non-sinusoidal) loads
  • Neutral bus size configured to accommodate at least 200% of the rated current compensates for increased neutral currents found in non-linear loads, thus reducing heat
  • Transformers include a versatile bonding/grounding bar affixed to the bottom panel as standard to provide compliance with NEC 450.10(A)
  • The core and coil assembly is grounded to the transformer enclosure by means of a visible flexible copper ground strap
  • Reduced core flux density
  • Coils designed to minimize stray losses
  • Electrostatic shield reduces transient noise in the system which may affect sensitive computer loads